Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Current limitations

  • Events about problems in Zabbix with the a duration of less than 1 minute may not be synchronized to Dynatrace

  • As events cannot be closed in Dynatrace, problems in Dynatrace will close automatically after 15 minutes if the status in Zabbix does not persist

  • TAGs are only added to Dynatrace, not removed

  • Ports are only added to Dynatrace, not removed (limitation on Dynatrace processing)because the Zabbix is polled at a specified time in the configuration field Dynatrace problem resend time. Value can be set to a minute or more.

  • Problems in Dynatrace are closed at least one minute after the extension detects the problem has been resolved in Zabbix. Closing interval is equal to the configuration field Dynatrace problem resend time

  • Ports are not readable from configuration so the Dynatrace custom device has only IP for interconnections with other Dynatrace objects

  • Zabbix acknowledges are part of Dynatrace event information, not Dynatrace problem