Current limitations
Events about problems in Zabbix with the a duration of less than 1 minute may not be synchronized to Dynatrace and because the Zabbix API is polled each minuteat a specified time in the configuration field
Dynatrace problem resend time
. Value can be set to a minute or more.Problems in Dynatrace are closed at least one minute after the extension detects the problem has been resolved in Zabbix. So it may take at least 2 minutes to close a problem in Dynatrace when Zabbix problem is resolved.
Host tags are only added to Dynatrace, not removed from Dynatrace custom device entities created by the extension.
Monitored ports are only added to Dynatrace, not removed (limitation on Dynatrace processing)
Acknowledges in Zabbix are not synchronized to comments of Dynatrace problems. Zabbix Closing interval is equal to the configuration field
Dynatrace problem resend time
Ports are not readable from configuration so the Dynatrace custom device has only IP for interconnections with other Dynatrace objects
Zabbix acknowledges are part of Dynatrace event information, not a Dynatrace problem.